1. Cut field coil leads at connector terminal on both
ends of connector and strip 1/4 inch of insulation.
See Figure 1.
Figure 2 — A9-098 Field Coil Connector Assembly
Figure 3 — Splicing to Field Coil Wires
Figure 4 — Field Coil Connector Assembly
Figure 1 — Clipping Off Old Connector
2. Connect new field coil connector assembly (see
Figure 2) via splices to existing field coil wires,
then crimp them securely (see Figure 3):
red to red
brown to brown
white to white
black to black
3. Use heat gun to seal the four splices.
4. Make sure male connector is securely connected
to the female connector inside the control unit.
See Figure 4.
This kit contains a larger sized connector assembly than what it may be replacing.
Be sure to replace both sides of connector if this is the case.
Continue to page 2
CAUTION
This symbol used in these instruc-
tions indicates presence of
hazard(s) that will or can cause
minor personal injury or property
damage if ignored.
Red wire
Brown wire
Black wire
White wire