TG0059A
Section A: Wiring Diagrams
Figure 3 — N1326-1 Alternator with N3007 Regulator Wiring Diagram
Figure 2 — N1326-1 Alternator Terminals
(N3007 Regulator Attached to Alternator)
Output
receptacle
CEN N1326-1 Alternator
Description and Operation
N1326-1 28 V (300 A) alternator is self-rectifying.
All windings and current-transmitting components
are non-moving, so there are no brushes or slip rings
to wear out. Load-dump protection limits peak volt-
age to less than 55 volts during maximum load
change over speed range in batteryless operation.
Ignition switch energizes regulator, and then field coil
is energized.
N3007 regulator furnished with this unit is flat
temperature compensated at 27.7±0.3 V at 72 F.
B terminal
(one on each side
of DE housing)
Regulator
receptacle
Figure 1 — N1326-1 Control Assembly